logo

Einzelheiten zu den Produkten

Created with Pixso. Zu Hause Created with Pixso. Produits Created with Pixso.
Niederspannungs-Schutz-Geräte
Created with Pixso.

Yaskawa Absolute Encoder Plug-in UTSAH-B17BBF For SGMDH-45A2AB ready to be installed

Yaskawa Absolute Encoder Plug-in UTSAH-B17BBF For SGMDH-45A2AB ready to be installed

Markenbezeichnung: Yaskawa
Modellnummer: UTSAH-B17BBF
MOQ: 1
Preis: Negotiations
Einzelheiten
Herkunftsort:
Japan
Modell:
UTSAH-B17BBF
Herkunftsort:
Japan
Serie:
UT-Reihe
Auflösung:
Bit 17
Verpackung Informationen:
Neue Originalbox
Beschreibung des Produkts

Yaskawa Absolute Encoder Plug-in UTSAH-B17BBF For SGMDH-45A2AB ready to be installed






QUICK DETAILS

  1. Brand :Yaskawa
  2. Model :UTSAH-B17BBF
  3. Place of Origin :Japan



DESCRIPTION

  • Servo Motor Encoder
  • Yaskawa Electric
  • Internal encoders




Item specifics
Model Number:UTSAH-B17BBF

Power Supply:DCMotor

Type:Amplifieris_

customized:yes

Install Style:Plug-in

Frequency:High Frequency

Function:Power Triode

Construction:Point Contact

TypeStructure:PNP

Type:AmplifierSpecial

Function:Common Point Contact Diode





OTHER SUPERIOR PRODUCTS

Yasakawa Motor, Driver SG- Mitsubishi Motor HC-,HA-
Westinghouse Modules 1C-,5X- Emerson VE-,KJ-
Honeywell TC-,TK- GE Modules IC -
Fanuc motor A0- Yokogawa transmitter EJA-
SIMILAR PRODUCTS
UTMAH-B12BD8V - Yaskawa - Internal encoders
UTMAHB12BD8V - Yaskawa - Internal encoders
UTMAH-B12BDYR7 - Yaskawa - Internal encoders
UTMAHB12BDYR7 - Yaskawa - Internal encoders
UTMAH-B12BDYR6 - Yaskawa - Internal encoders
UTMAHB12BDYR6 - Yaskawa - Internal encoders
UTMAH-B15AS8F - Yaskawa - Internal encoders
UTMAHB15AS8F - Yaskawa - Internal encoders
UTMAH-B15AS19B - Yaskawa - Internal encoders
UTMAHB15AS19B - Yaskawa - Internal encoders
UTMAH-B15AS4OB - Yaskawa - Internal encoders
UTMAHB15AS4OB - Yaskawa - Internal encoders
UTMAH-B15BS13 - Yaskawa - Internal encoders
UTMAHB15BS13 - Yaskawa - Internal encoders
UTMAH-B15AR - Yaskawa - Internal encoders
UTMAHB15AR - Yaskawa - Internal encoders
UTMAH-B15DSB - Yaskawa - Internal encoders
UTMAHB15DSB - Yaskawa - Internal encoders
UTMAH-B15AS3DB - Yaskawa - Internal encoders
UTMAHB15AS3DB - Yaskawa - Internal encoders
UTMAH-B15AS158 - Yaskawa - Internal encoders
UTMAHB15AS158 - Yaskawa - Internal encoders
UTMAH-B15AS4NB - Yaskawa - Internal encoders
UTMAHB15AS4NB - Yaskawa - Internal encoders
UTMAH-B15AS15B - Yaskawa - Internal encoders
UTMAHB15AS15B - Yaskawa - Internal encoders
UTMAH-B15AS4MB - Yaskawa - Internal encoders
UTMAHB15AS4MB - Yaskawa - Internal encoders
UTOPE-40AWT - Yaskawa - Internal encoders
UTOPE40AWT - Yaskawa - Internal encoders
UTOPE-25ZDL - Yaskawa - Internal encoders
UTOPE25ZDL - Yaskawa - Internal encoders
UTOPE-300WB80 - Yaskawa - Internal encoders
UTOPE300WB80 - Yaskawa - Internal encoder






Installing the Option
Refer to the instructions below to install the option.
1. Shut off power to the drive, wait the appropriate amount of time for voltage to
dissipate, then remove the digital operator (E), front cover (D), and terminal cover
(F). Refer to the Quick Start Guide packaged with the drive.
DANGER! Electrical Shock Hazard. Disconnect all power to the drive and wait at least the amount of time
specified on the drive front cover safety label. After all indicators are off, measure the DC bus voltage to
confirm safe level, and check for unsafe voltages before servicing to prevent electric shock. The internal
capacitor remains charged even after the power supply is turned off.
NOTICE: Damage to Equipment. Observe proper electrostatic discharge procedures (ESD) when handling
the option, drive, and circuit boards. Failure to comply may result in ESD damage to circuitry.




Prepare and connect the wire ends as shown in Figure 6 and Figure 7. Refer to
Wire Gauges and Tightening Torques on page 28 to confirm that the proper tightening torque is applied to each terminal. Take particular precaution to ensure
that each wire is properly connected and wire insulation is not accidentally pinched
into electrical terminals.
WARNING! Fire Hazard. Tighten all terminal screws according to the specified tightening torque. Loose
electrical connections could result in death or serious injury by fire due to overheating electrical connections.
Tightening screws beyond the specified tightening torque may result in erroneous operation, damage the
terminal block, or cause a fire.
NOTICE: Heat shrink tubing or electrical tape may be required to ensure that cable shielding does not
contact other wiring. Insufficient insulation may cause a short circuit and damage the option or drive.