Technical Specifications
Specification Details
Maximum voltage between any terminal and ground 600 V
Overvoltage protection 6 kV peak, compliant with IEC 61010-1 600 V CAT III, pollution degree 2
Display Digital: 6000 counts, updated 4 times per second
Bar chart: 33 segments, updated 32 segments per second
Operating temperature -10 °C to +50 °C
Storage temperature -40 °C to +60 °C
Battery type 9 V alkaline battery, NEDA 1604A/IEC 6LR61
Battery life Typically 400 hours, without backlight
Accuracy Specifications
Measurement Type Range/Resolution Accuracy
DC millivolt 600.0 mV / 0.1 mV ± (0.5% + 2)
DC voltage 6.000 V / 0.001 V
60.00 V / 0.01 V
600.00 V / 0.1 V
± (0.5% + 2)
Auto Volt 600.0 V / 0.1 V ± (2.0% + 3) DC, 45 Hz to 500 Hz
± (4.0% + 3) 500 Hz to 1 kHz
AC Voltage (mV) True RMS 600.0 mV / 0.1 mV ± (1.0% + 3) DC, 45 Hz to 500 Hz
± (2.0% + 3) 500 Hz to 1 kHz
AC Voltage True RMS 6.000 V / 0.001 V
60.00 V / 0.01 V
600.0 V / 0.1 V
± (1.0% + 3) DC, 45 Hz to 500 Hz
± (2.0% + 3) 500 Hz to 1 kHz
Continuity 600 Ω / 1 Ω < 20 Ω with buzzer on, > 250 Ω with buzzer off; detects open or short circuits for 500 μs or longer
Ohm Measurement 600.0 Ω / 0.1 Ω
6.000 kΩ / 0.001 kΩ
60.00 kΩ / 0.01 kΩ
600.0 kΩ / 0.1 kΩ
6.000 MΩ / 0.001 MΩ
± (0.9% + 1)
Ohm Measurement 40.00 MΩ / 0.01 MΩ ± (5% + 2)
Diode Testing 2.00 V / 0.001 V ± (0.9% + 2)
Capacitance Measurement 1000 nF / 1 nF
10.00 μF / 0.01 μF
100.0 μF / 0.1 μF
9999 μF / 1 μF
100 μF to 1000 μF
± (1.9% + 2)
Capacitance Measurement > 1000 μF ± (5% + 20%)
Lo-Z Capacitor 1 nF to 500 μF ± (10% + 2)
Temperature (Type K Thermocouple) -40 °C to 400 °C / 0.1 °C ± (1% + 10)
Temperature (Type K Thermocouple) -40 °F to 752 °F / 0.2 °F ± (1% + 18)
AC μA True RMS (45 Hz to 500 Hz) 600.0 μA / 0.1 μA ± (1.5% + 3)
DC Microamp 600.0 μA / 0.1 μA ± (1.0% + 2)
Hz (Voltage or Current Input) 99.99 Hz / 0.01 Hz
999.9 Hz / 0.1 Hz
9.999 kHz / 0.001 Hz
50.00 kHz / 0.01 Hz
± (0.1% + 2)
Notes
  • All AC voltage ranges (except Auto-V/LoZ) are specified as 1% to 100% of the range. The starting range for Auto-V/LoZ is specified as 0.0 V.
  • Temperature error (accuracy) does not include thermocouple probe error.
  • Frequency is 5 Hz to 50 kHz for AC coupling and AC voltage. Frequency is 45 Hz to 5 kHz for DC coupling and AC current.
Mechanical and General Specifications
  • Dimensions: 167 x 84 x 46 mm (6.57 x 3.31 x 1.82 in)
  • Weight: 550 g
  • Warranty: 3 years
  • Fluke 116C Handheld True RMS Digital Multimeter - HVAC Professional Tester with Temperature & Microamp Measurement 0